GE - BOILER/GENERATOR MODEL – GE-12 to GE-180 XL ADDITIONAL EQUIPMENT:
(For larger units consult factory or dealer).
WATER FEED SYSTEMS: (WATER SOLENOIDS, WATER PUMPS, and RETURN/MAKEUP TANKS).
Boiler water feed equipment is needed for the operation of the boiler/generator.
Specify the proper water feed devices for the particular need. Order w/ models as follows:
(Std. 0-100 PSI Systems Listed here). PLEASE ASK FOR PRICES
LOW PRESSURE LINE FEED (ALL MODELS). 120 Volts GE-12-180 S-LP 1 $
Used only on boilers 0-50 PSI operating when the water line pressure
Is greater at least 15 PSI than the boiler operating pressure.
Includes solenoid, strainer and check valve.
HI-PRESSURE LINE FEED 120 Volts. GE-12-180
Used on boiler systems of 0-100 PSI operating pressure SP-HP 11 $
Features feed pump&motor, solenoid, strainer and check valve.
CONDENSATE RETURN/MAKE-UP TANK WATER SYSTEM
120V.System). Hi & Low Pressure
Complete tank w/float assembly and feed pump&motor, strainer,
Stop valve to pump & check valve.( SEE: Compact mountings on page 1for frame and piping).
15 GL. Tank with 1/3 HP pump&motor for models GE-12-72 TP-HP 20 $
25 GL. Tank with 1/3 HP pump&motor for models GE-100-180 TP-HP 21 $
CODE A.S.M.E. BLOWDOWN TANKS
Coded ASME Blowdown tank sized for Models GE-12-72 BDT-ASME 30 $
Coded ASME Blowdown tank sized for models GE-100-180 BDT-ASME 31 $
NON-Code Blowdown tank for GE12-72 List $ and for GE-1010-180 $
(OPTIONAL).OTHER EQUIPMENT FOR BOILERS
1" Automatic/Electric Blowdown valve w/ timer and time of day GE-12 -180 BD-AT 100 $
Extra pressure control and manual switch to operate on 50% power GE-48-180
P.Switch 100 PSI $
P.Switch 150 PSI $
TRANSFORMERS (Step-down transf.120V. Controls from primary main Power) Installed:
.25 KVA for boilers with solenoid feed mod. GE-12-72 TRAN 250 $
.50KVA for boilers " " " GE-100-180 TRAN 500 $
1.5KVA for boilers with 1/3rd & ½ HP motor & pump GE-12-180 TRAN 1500 $
SOLID STATE PROGRESSIVE Sequencer w/proportional pressure operating
(optional requirement on larger boilers GE-100 and larger). GE-100-180 STEP CT 100 $
SECOND LOW-WATER CUTOFF W/ MANUAL RESET:
Required: California, Texas, Washington, Iowa, Massachusetts, Nevada
North Carolina, Arizona. Consult Factory for other requirements in other States.
Electronic Auxiliary low-water cutoff control wired to boiler system.GE-24-180: SEC.LLCO INCLUDED
Also needed in States which have adopted the ASME CSD-1 Controls.
(Note that other Companies charge up to $800.- for the sec.LLCO and CSD1 compliance)
CSD-1 Controls: All our boilers meet ASME CSD-1, order: CSD-1 (Specify): INCLUDED
Secondary HI-LIMIT Pressure control: Standard installed on all models: INCLUDED
Vacuum breaker installed on all units w/o solenoid feed.
OPTIONAL Air bleed valve installed on boilers of 30 psi or less add $ 75.00 List.